Module 3 · 6 min read · Free chapter
Electricity at home: power, AC and safety
One unit on the electricity bill is one kilowatt-hour, equal to 3.6 × 10⁶ joules. Indian homes get AC at 220–230 V and 50 Hz. A fuse has a low melting point and is placed in series with the live wire. The earth wire is green, and bulb filaments are made of tungsten.
Start from zero: why wires get hot
When current flows through a wire, the moving electrons keep bumping into the atoms of the metal. These collisions turn some electrical energy into heat. This is the heating effect of current.
The heat produced is given by Joule's law: H = I²Rt, where I is the current, R the resistance and t the time. Doubling the current makes four times the heat, which is why too much current is dangerous.
We use this effect every day in heaters, irons, geysers and toasters, whose coils have high resistance. The same effect also powers the fuse, which you will meet below.
The rate at which a device uses energy is its power. Electric power is P = V × I, which can also be written as I²R or V²/R. It is measured in watts (W), and 1 kilowatt = 1,000 W.
What is one 'unit' on the bill?
The joule is too small for household use, so electricity boards charge by the kilowatt-hour (kWh). One kWh is the energy used by a 1,000 W device running for one hour. On your bill, 1 kWh is called one 'unit'.
Since energy = power × time, a 100 W bulb running for 10 hours uses 100 × 10 = 1,000 Wh, which is 1 unit. A 2,000 W geyser running for half an hour also uses 1 unit.
In joules, 1 kWh = 3.6 × 10⁶ J, because 1,000 W × 3,600 s = 3,600,000 J. The electricity meter at your home counts energy in kWh.
AC and DC: two kinds of current
A cell pushes current in one direction only. This is direct current (DC), and it is what you get from batteries and solar panels.
The current from the wall socket keeps reversing its direction, many times every second. This is alternating current (AC). In India, the household supply is AC at 220–230 V and 50 Hz, which means it changes direction back and forth 50 times a second. The USA uses about 110–120 V at 60 Hz.
Why do power grids use AC? Its voltage can be raised or lowered easily with transformers. Power is sent over long lines at very high voltage, which cuts the losses, and then stepped down near your home.
Many gadgets like phones and laptops need DC. Their adapter contains a rectifier, which converts AC from the socket into DC.
Fuses and MCBs
If too many appliances run on one line, the current becomes too large. This is called overloading. If the live and neutral wires touch directly, the resistance drops almost to zero and a huge current flows. This is a short circuit.
Both can overheat the wiring and start a fire. A fuse prevents this. It is a short piece of thin wire with a low melting point, traditionally an alloy of tin and lead, connected in series with the live wire.
When the current crosses a safe limit, the fuse wire melts and breaks the circuit. Modern homes use a miniature circuit breaker (MCB), which does the same job but simply trips off and can be switched on again after the fault is fixed.
Fuses, MCBs and switches are always placed in the live wire. That way, when they are off, the appliance is fully cut off from the dangerous voltage.
Live, neutral and earth
Household wiring uses three wires, each with its own colour. The live wire carries the current in and has red or brown insulation. The neutral wire completes the circuit and is black or blue. The earth wire is green or green-yellow.
The earth wire is joined to a metal plate buried deep in moist ground. It is connected to the metal body of appliances like irons, fridges, washing machines and geysers.
Suppose a loose wire inside an iron touches its metal body. Without earthing, anyone touching the iron would get a shock. With earthing, the leaking current flows safely into the ground instead of through the person, and the fuse or MCB usually trips. This is why heavy appliances come with a three-pin plug.
From the filament bulb to the LED
In 1879, Thomas Edison made a practical incandescent bulb. Current heats a thin coiled filament until it glows white-hot.
The filament is made of tungsten, because it has a very high melting point of about 3,400 °C. The bulb is filled with an inert gas such as argon or nitrogen, so the hot filament does not burn up.
The old bulb is very wasteful, as most of its energy turns into heat, not light. A CFL gives the same light for much less power, and an LED is even better and lasts far longer.
To speed up the switch, India launched the UJALA scheme in 2015, which gave out crores of LED bulbs at low cost. This cut household bills and reduced the load on power plants.
Star labels on appliances
When you buy a fan, fridge or AC in India, you will see a label with 1 to 5 stars. The Bureau of Energy Efficiency (BEE), set up under the Energy Conservation Act 2001, runs this programme.
More stars mean the appliance uses less electricity for the same work. A 5-star AC may cost more to buy but saves money on every bill for years.
Mains lens: saving electricity at scale
Every unit saved at home is a unit that a power plant does not have to make. The questions in this section are practice questions written by us, not past papers.
Angle 1: efficient lighting. Moving from filament bulbs to LEDs under UJALA cut lighting power use sharply. It showed that bulk buying can bring down prices fast.
Angle 2: appliance standards. Star labels let buyers compare running costs. Raising the standards over time pushes makers to build better products.
Angle 3: climate link. Most of India's electricity still comes from coal, so saving power also cuts carbon emissions.
Practice questions:
- Why does an LED bulb save more energy than a filament bulb? (150 words)
- Energy efficiency is the cheapest source of new energy. Discuss with reference to India's lighting and appliance programmes. (250 words)
Answer plan for the second question: Begin with why a saved unit costs less than a new one. Then cover UJALA and star labels with their gains. End with the link to emissions and household savings.
Quick revision
- Heating effect: H = I²Rt. Power P = VI, in watts.
- 1 unit = 1 kWh = 3.6 × 10⁶ J. A 100 W bulb for 10 h uses 1 unit.
- India: AC at 220–230 V, 50 Hz. Grids use AC because transformers change voltage easily.
- Fuse: low melting point, tin-lead alloy, in series with the live wire. MCB can be reset.
- Wires: live red or brown, neutral black or blue, earth green.
- Filament is tungsten, gas is argon or nitrogen. UJALA (2015) spread LEDs.
| Item | Key fact |
|---|---|
| Fuse wire | Low melting point, in series |
| Bulb filament | Tungsten, about 3,400 °C |
| Heater coil | Nichrome |
| Earth wire | Green, joined to metal body |