Civil Engineering‹ 0:00 studied

Module 2 · 12 min read · Free chapter

Pile, well and machine foundations

In short

A pile carries Qu = Qs + Qb; in clay f = α cu and Qb = 9 cu Ab. Groups in clay lose efficiency (Converse-Labarre) and are also checked as a block with Nc = 5.14, taking the lower value. Wells go below maximum river scour, and machine foundations are tuned away from resonance.

What are you preparing for? We show the practice and previous year questions of your exam.

Start from zero: when footings are not enough

Try to stand a pole upright in loose sand at the beach. It falls over. Push it down until it reaches the firm sand below, and it stands. That is the idea of a deep foundation: when the soil near the surface cannot carry the load, take the load down to soil that can.

Piles are used when:

  • the good soil lies deep, and the top layers are soft clay, fill or loose sand;
  • the water table is high, so open excavation for a footing is hard;
  • loads are heavy, inclined or uplifting, as in towers, bridges and jetties;
  • settlement must be kept small, as under sensitive machines;
  • the river bed may be scoured away, as under bridge piers.

Elements under about 750 mm diameter are usually called piles. Larger drilled shafts, drilled piers and caissons, are 750 mm or more and carry their load mostly in end bearing. A well foundation is a large hollow caisson sunk into a river bed.

Why it matters. Most of the Gangetic plain has deep soft alluvium. Almost every major bridge, flyover and power plant there stands on piles or wells.

Capacity of a single pile

A pile carries load in two ways: by friction along its shaft, Qs, and by bearing at its tip, Qb.

Qu = Qs + Qb

A pile that gets most of its capacity from the tip resting on rock or dense sand is an end-bearing pile. One that gets most of it from friction in soft soil is a friction pile. When load is first applied, only the upper part of the shaft works; as the load grows, friction is mobilised further down, and the tip takes its share last.

Piles in clay. The soil sticks to the shaft by adhesion, f = α cu, where cu is the undrained strength and α is the adhesion factor. For soft clay α is close to 1; for stiff clay it is lower, often 0.5 or less, because the clay does not fully grip the shaft. At the tip, a deep foundation in clay has Nc = 9, so:

Qu = α cu (π D L) + 9 cu (π D²/4)

Piles in sand. Friction per unit area is K σ′v tan δ, where K is the earth pressure coefficient on the shaft and δ is the pile–soil friction angle. Tip resistance is Qb = σ′v Nq Ab. Tests show that σ′v used in these formulas stops growing below a critical depth, roughly 15 to 20 diameters, so capacity does not keep rising with length.

A factor of safety of 2 on the ultimate value is commonly used for a single pile when its capacity is confirmed by tests or reliable soil data.

Negative skin friction. If the soil around a pile settles more than the pile, friction acts downwards and drags the pile. This happens when fresh fill is placed over soft clay, when the water table is lowered, or when a soft layer is still consolidating. The downdrag adds load instead of carrying it, and many piles have failed by settlement because it was ignored.

Dynamic formulae and pile load tests

While a pile is being driven, the hammer gives a known energy per blow and the pile moves down by a measurable set. Dynamic formulae turn that into a capacity. The simplest is the Engineering News formula:

Qa = W H / [6 (S + C)]

Here W is the hammer weight, H the drop height, S the set per blow (in cm, averaged over the last few blows), and C a constant, 2.5 cm for a drop hammer. The 6 includes a large factor of safety. Hiley's formula is more detailed: it accounts for hammer efficiency, the coefficient of restitution and the elastic compression of the pile, cap and soil.

Dynamic formulae work reasonably in sands and gravels, where capacity during driving is close to capacity later. In saturated clays they fail: driving raises pore pressure and remoulds the clay, so the resistance during driving is not the resistance after the clay recovers. Static formulae, from soil strength, are used there.

The most reliable check is the pile load test. A test pile is loaded in steps against a reaction (kentledge or anchor piles), and each step is held until settlement stops. Initial tests are done on trial piles before the job, often to failure; routine tests are done on a few working piles to confirm them. A common rule takes the safe load as the lower of two-thirds of the load at 12 mm settlement and half the load at a settlement of 10% of the pile diameter.

Tests for uplift and lateral load follow the same idea. A pile under lateral load acts as a beam on an elastic soil: the top deflects, the bending moment peaks a few diameters below the ground, and short stiff piles rotate while long piles bend.

Pile groups

Piles are almost always used in groups under a common pile cap. A group of n piles does not always carry n times the load of one pile, because the stressed zones around close piles overlap. Group efficiency is:

η = Qgroup / (n × Qsingle)

For friction piles in clay, a common estimate is the Converse-Labarre formula for a group of m rows with n piles in each:

η = 1 − θ [(n − 1) m + (m − 1) n] / (90 m n), where θ = tan⁻¹(d/s) in degrees

Wider spacing s means smaller θ and higher efficiency. In sand, driving compacts the soil between piles, and efficiency is usually taken as 100% or even more.

When piles in clay are closer than about 3 diameters, the whole group with the soil between the piles may sink as one block. The block is drawn tangent to the outer piles, so its width is W = (number of spaces) × s + d. Its capacity is:

Qblock = 2 (W + L) D α c + 1.3 c Nc W L

Here D is the pile length and Nc = 5.14, the shallow value, not 9, because the block is wide compared with its depth effect. The design capacity of the group is the lower of the block value and the value from individual pile failure.

A worked case. Nine piles of 0.4 m diameter, 9 m long, are set in a 3 × 3 pattern at 1.2 m spacing in clay with qu = 100 kPa, so c = 50 kPa; take α = 1.

  • Block: W = L = 2 × 1.2 + 0.4 = 2.8 m. Qs = 50 × 4 × 2.8 × 9 = 5040 kN; Qb = 1.3 × 50 × 5.14 × 2.8² ≈ 2619 kN; total ≈ 7659 kN; with F = 3, about 2553 kN.
  • Single pile: Qs = 50 × π × 0.4 × 9 ≈ 565 kN; Qb = 9 × 50 × π × 0.4²/4 ≈ 57 kN; Qu ≈ 622 kN; with F = 2, about 311 kN.
  • Efficiency: θ = tan⁻¹(0.4/1.2) ≈ 18.4°; η = 1 − 18.4 × 12 / 810 ≈ 0.73.
  • Group by individual failure: 0.73 × 9 × 311 ≈ 2043 kN, lower than the block value, so this governs.

Settlement of a group is far larger than that of a single pile under the same load per pile, because the group stresses a much deeper zone. For friction piles in uniform clay, the load is placed on an equivalent raft at two-thirds of the pile length and spread at 2:1 to find the stress in the clay below. For piles resting on a stiff layer, the equivalent raft goes at the pile tip.

Try it yourself. The ujjwalinfra pile design tool works out shaft and base capacity for a single pile and a group, so you can change spacing and watch the efficiency move.

Well foundations

Big rivers like the Ganga and the Kosi scour their beds deeply in floods, sometimes by tens of metres. A pier on piles can lose its lateral support when the bed washes away. India's answer for over a century has been the well foundation: a large, heavy, hollow shaft sunk deep below the deepest scour.

The parts, from bottom to top, are:

  • Cutting edge, a steel edge that cuts into the soil as the well sinks.
  • Well curb, a tapered reinforced concrete ring above the cutting edge that guides sinking.
  • Steining, the thick wall of the well, whose weight helps it sink and which carries the load.
  • Bottom plug, concrete placed under water at the base once founding level is reached.
  • Sand filling inside the dredge hole, then a top plug.
  • Well cap, the slab on which the pier stands.

The well is sunk by dredging soil from inside while its weight pushes it down; kentledge is added when friction resists. The big risks during sinking are tilt and shift, which must be kept within limits and corrected as the well goes down. The founding level is set by the maximum scour depth plus a grip length below it, so that the well keeps enough soil around it in the worst flood.

Try it yourself. The ujjwalinfra scour depth tool works out the normal and maximum scour for a river crossing, which sets how deep a bridge well has to go.

Machine foundations

A footing under a building carries a load that hardly changes. A foundation under a compressor, turbine, forging hammer or diesel generator is shaken every second. Because the block and soil are accelerated, inertia forces develop, and the problem becomes dynamic.

The simplest model treats the block on soil as a mass m on a spring of stiffness k with damping c:

m ü + c u̇ + k u = F(t)

The natural frequency is ωn = √(k/m). Damping can be over-critical, critical or under-critical; soils usually give under-damped behaviour, so the block vibrates and slowly settles down after a disturbance.

The loads are of three kinds:

  • Periodic, from rotating or reciprocating machines; an unbalanced mass m at eccentricity e spinning at ω gives a force m e ω², which grows with the square of speed.
  • Transient, such as a sudden start or stop.
  • Impulsive, such as a forging hammer blow.

The central design rule is to avoid resonance: if the operating frequency is close to the natural frequency, the amplitude grows very large even under a small force. So the block's mass and base area are chosen to keep the natural frequency well away from the operating speed, either well above it (a stiff, high-tuned foundation) or well below it (a low-tuned one). The amplitude of vibration must also stay within limits set for the machine and for people nearby.

Why it matters. A power plant turbine that resonates can wreck its own foundation and the machine within weeks. Machine foundations are designed for vibration first and bearing capacity second.

Descriptive lens: how this topic is asked in written papers

Written papers on deep foundations tend to ask:

  1. When and why piles or wells are chosen, and how piles are classified.
  2. Compute single pile and group capacity, with efficiency and block checks.
  3. Explain negative skin friction, pile load tests, or the limits of dynamic formulae.
  4. Describe the parts and sinking of a well foundation, or the design criteria for machine foundations.

Practice questions (our own, not previous-year questions).

  1. What is negative skin friction? Give two site situations where it develops and two ways to reduce it. (10 marks)
  2. Describe the components of a well foundation and the problems of tilt and shift during sinking. (10 marks)
  3. A 2 × 2 group of 0.5 m diameter friction piles, 12 m long, at 1.5 m spacing, is driven into soft clay with cu = 40 kPa and α = 1. Find the group capacity from individual failure (Converse-Labarre) and from block failure, and state the design value with F = 2.5. (15 marks)

Answer plan for question 3.

  • Single pile: Qs = 40 × π × 0.5 × 12 ≈ 754 kN; with Ab = π × 0.5²/4 ≈ 0.196 m², Qb = 9 × 40 × 0.196 ≈ 71 kN; Qu ≈ 825 kN.
  • θ = tan⁻¹(0.5/1.5) ≈ 18.4°; m = n = 2: η = 1 − 18.4 × [(1)(2) + (1)(2)] / (90 × 4) ≈ 0.795; group ≈ 0.795 × 4 × 825 ≈ 2620 kN.
  • Block: W = L = 1.5 + 0.5 = 2.0 m; Qs = 2 × 4 × 12 × 40 = 3840 kN; Qb = 1.3 × 40 × 5.14 × 4 ≈ 1069 kN; total ≈ 4909 kN.
  • Lower is about 2620 kN; with F = 2.5, design group capacity ≈ 1050 kN. Note that spacing of 3 diameters means block failure does not govern.

Quick revision

  • Qu = Qs + Qb; F ≈ 2 for a single pile.
  • Clay: f = α cu (α ≈ 1 soft, < 1 stiff); Qb = 9 cu Ab.
  • Sand: f = K σ′v tan δ; Qb = σ′v Nq Ab; σ′v capped below the critical depth.
  • Negative skin friction: soil settles more than the pile and drags it down.
  • Dynamic formulae (Engineering News, Hiley) suit sand, not saturated clay.
  • Converse-Labarre: η = 1 − θ [(n − 1) m + (m − 1) n] / (90 m n), θ = tan⁻¹(d/s).
  • Block in clay (s < 3d): Nc = 5.14; design = lower of block and η n Qsingle.
  • Group settlement: equivalent raft at 2L/3 (friction piles) or at the tip (end bearing).
  • Well: cutting edge, curb, steining, bottom plug, sand filling, top plug, well cap; depth set by maximum scour.
  • Machine foundation: ωn = √(k/m); force m e ω²; avoid resonance.

Check yourself

Exam-style questions on this chapter. Pick an answer to see the explanation. 0 of 13 answered

  1. Piles are a suitable choice when:

  2. The base resistance of a pile in clay is usually taken as:

  3. For a pile in clay, the adhesion factor α is:

  4. A 0.4 m diameter pile, 9 m long, is in clay with cu = 50 kPa and α = 1. Its ultimate capacity is about:

  5. In the Converse-Labarre formula, θ is:

  6. When the block capacity of a pile group in clay is computed, the Nc used for the block base is:

  7. The design capacity of a pile group in clay is:

  8. For settlement of a friction pile group in uniform clay, the load is placed on an equivalent raft at:

  9. Negative skin friction on a pile develops when:

  10. Dynamic pile formulae are least reliable in:

  11. The part of a well foundation that forms its main wall and carries load is the:

  12. To avoid resonance in a machine foundation, the operating frequency should be:

  13. The force from an unbalanced mass m at eccentricity e rotating at angular speed ω is:

Previous year questions

Previous year questions for UPSC CSE will appear here once each one is checked word for word against the official question paper.

Learn with AI

A tutor that asks instead of telling, a partner that argues the other side, and this chapter told through your own district.

Tell the tutor what you are stuck on. It will guide you with questions and give the answer after a few tries.

Frequently asked questions

What is negative skin friction?

Downward drag on a pile when surrounding soil settles more than the pile, adding load instead of support.

What Nc is used for the block failure of a pile group?

5.14, the shallow value, while a single pile tip in clay uses 9.

Why are dynamic pile formulae unreliable in clay?

Driving remoulds clay and raises pore pressure, so driving resistance differs from long-term capacity.

What decides the depth of a well foundation?

The maximum scour depth plus a grip length below it, along with bearing capacity.

More in this module: Foundation engineering

Official sources

Facts in this chapter were checked against these official sources.

  1. GATE 2026 Civil Engineering (CE) syllabus, IIT Guwahati
  2. BPSC Assistant Engineer (Civil) syllabus, Paper 5
  3. NPTEL Foundation Engineering (IIT Kharagpur, 105105185), Lecture 38: Pile foundation
  4. NPTEL Foundation Engineering (IIT Kharagpur, 105105185), Lecture 40: Pile capacity
  5. NPTEL Foundation Engineering (IIT Kharagpur, 105105185), Lecture 41: Pile capacity (contd.)
  6. NPTEL Foundation Engineering (IIT Kharagpur, 105105185), Lecture 44: Pile group capacity
  7. NPTEL Foundation Engineering (IIT Kharagpur, 105105185), Lecture 45: Pile settlement
  8. NPTEL Foundation Engineering (IIT Kharagpur, 105105185), Lecture 53: Machine foundation
  9. NPTEL Foundation Engineering (IIT Kharagpur, 105105185), Lecture 54: Machine foundation (contd.)