Module 2 · 15 min read · Free chapter
Earth pressure and retaining walls
A wall moving away from the soil gets active pressure, one pushed into it gets passive pressure, and a fixed wall gets at-rest pressure. Rankine gives Ka = tan²(45° − φ/2), Coulomb adds wall friction. Walls are checked for overturning, sliding and base pressure, with drainage behind them.
Start from zero: why soil pushes sideways
Fill a bucket with dry sand and then slowly lift the bucket away. The sand does not stand as a cylinder. It slumps into a cone, because the grains need sideways support to stay at a steep face.
Whenever we want soil to stand steeper than it would on its own, something must supply that support. A road cut on a hillside, a basement, a bridge abutment, the bank of a canal and the sides of a deep trench all need it. The structure that provides it is a retaining wall, and the push the soil exerts on it is the lateral earth pressure.
The key idea of this chapter is that this push is not fixed. It depends on whether the wall moves, and in which direction. A wall that leans away even slightly feels much less pressure than one that is held rigidly. A wall pushed into the soil meets far more resistance.
Why it matters. Retaining walls are among the most common structures a civil engineer designs, from small garden walls to highway walls over 10 m high. Their failure is sudden and often deadly, and nearly always comes from water pressure or earth pressure that was underestimated.
At rest, active and passive
Picture a rigid wall holding back soil and not moving at all. The soil next to it is in the same state as soil deep inside the ground, squeezed sideways by its neighbours. The ratio of horizontal to vertical effective stress here is the coefficient of earth pressure at rest, K0. For a normally consolidated soil, a widely used estimate is K0 = 1 − sin φ′, so a sand with φ′ = 30° has K0 = 0.5.
Now let the wall move slightly away from the soil. The soil follows, the horizontal stress drops, and the soil leans more and more on its own shear strength.
At a small movement the stress reaches a minimum and a wedge of soil slides down along a plane. This is the active state. The vertical stress is now the major principal stress, and the slip plane makes 45° + φ/2 with the horizontal.
Push the wall instead into the soil. The horizontal stress rises until the soil can resist no more, and a wedge is shoved up and out. This is the passive state, with a maximum horizontal stress. Now the horizontal stress is the major principal stress, and the slip plane is flatter, at 45° − φ/2 with the horizontal.
The movement needed is very different. The full active state comes with a wall movement of only about 0.001H to 0.005H, where H is the wall height. The full passive state needs roughly ten times as much, about 0.05H. In the at-rest state the Mohr circle sits below the failure envelope; in both the active and passive states it touches it.
Why it matters. A basement wall braced by floors cannot move, so it must be designed for at-rest pressure, which is about 50% more than active for φ = 30°. A free-standing wall that may tilt slightly can be designed for active pressure. Passive resistance in front of a wall helps, but only if the wall can move enough to mobilise it.
Rankine's theory
In 1857, Rankine looked at a soil element at the moment of failure. He assumed a smooth, vertical wall and a level backfill, so that the vertical and horizontal stresses on the wall are principal stresses. At failure, the Mohr circle of these two stresses touches the envelope τ = σ tan φ. Simple geometry of that circle then gives the ratio of the two stresses.
For the active state, the horizontal stress is the minor one:
σh = Ka σv, with Ka = (1 − sin φ)/(1 + sin φ) = tan²(45° − φ/2)
For the passive state, it is the major one:
σh = Kp σv, with Kp = (1 + sin φ)/(1 − sin φ) = tan²(45° + φ/2) = 1/Ka
For a dry cohesionless backfill, σv = γz, so the active pressure grows linearly with depth from zero at the top to Ka γ H at the base. The pressure diagram is a triangle, and its area is the total thrust per metre length:
Pa = ½ Ka γ H², acting at H/3 above the base
In the same way, Pp = ½ Kp γ H². For φ = 30°, Ka = 1/3 and Kp = 3, so passive resistance is nine times the active thrust. This is a useful number to remember.
The same answer comes from a different route. Take a trial wedge of soil behind the wall, cut off by a plane at angle β.
Draw its force polygon with its weight, the reaction on the slip plane and the wall thrust. Vary β until the thrust is critical, and the critical angle turns out to be 45° + φ/2 with the same Ka. This trial-wedge idea is the basis of Coulomb's theory below.
If the backfill slopes upwards at an angle β, Rankine's active coefficient becomes:
Ka = cos β × [cos β − √(cos²β − cos²φ)] / [cos β + √(cos²β − cos²φ)]
and the thrust acts parallel to the backfill surface, so it has both horizontal and vertical components.
Surcharge, water and layers
Real walls rarely hold a dry, uniform backfill with nothing on top. Three common additions change the pressure diagram, and each is handled by adding its own simple shape.
A uniform surcharge q, such as traffic or stored material on the backfill, raises the vertical stress by q at every depth. The lateral pressure therefore rises by Ka q everywhere, giving a rectangle of pressure over the full height with its resultant at H/2.
A water table in the backfill splits the effect into two parts. Below the water table, the soil grains press with the submerged unit weight γ′ = γsat − γw, so the earth pressure grows more slowly. But the water itself pushes on the wall with full hydrostatic pressure γw hw, and water does not get the Ka reduction, because it has no shear strength.
Take the worked case of an 8 m wall with a smooth vertical back, sand with γ = 18 kN/m³ and φ = 30° (Ka = 1/3), the water table 3 m below the top and a surcharge of 30 kPa:
- surcharge rectangle: 10 kPa × 8 m = 80 kN, at 4 m above the base,
- soil above water: ½ × 18 × 3 × 3 × 1/3 = 27 kN, at 6 m above the base,
- soil below water from the dry layer above: 18 kPa × 5 m = 90 kN, at 2.5 m,
- soil below water from its own weight: ½ × (18 − 9.81) × 5 × 5 × 1/3 ≈ 34.1 kN, at 5/3 m,
- water: ½ × 9.81 × 5² ≈ 122.6 kN, at 5/3 m.
The total thrust is about 354 kN per metre, acting about 2.74 m above the base. Notice that water alone gives a third of it.
For layered backfill, each layer uses its own Ka with the vertical stress at that depth, so the diagram can jump at a layer boundary.
Why it matters. Many retaining walls fail after heavy rain, not because the soil changed but because blocked drains let water build up behind them. Good drainage can cut the design thrust by a third.
Cohesive backfill and tension cracks
When the backfill has cohesion c as well as friction φ, Rankine's analysis gives:
pa = Ka γ z − 2c √Ka (active)
pp = Kp γ z + 2c √Kp (passive)
Cohesion reduces the active pressure and increases the passive resistance. Near the top of an active wall, the term 2c √Ka is larger than Ka γ z, so the formula gives a negative pressure, a pull. Soil cannot pull on a wall for long; it cracks instead.
The depth of these tension cracks is where the active pressure is zero:
zc = 2c / (γ √Ka)
Over this depth the soil stands by itself. Theory shows that a vertical cut in such soil can stand without support up to about twice this depth:
Hc = 4c / (γ √Ka), which becomes Hc = 4c/γ for a purely cohesive soil with φ = 0
A worked case shows the idea in reverse. A vertical cut in a saturated clay with γ = 20 kN/m³ failed when it reached 5.1 m. With φ = 0, 4c/γ = 5.1, so the cohesion was about c = 5.1 × 20 / 4 = 25.5 kPa.
In design, the negative part of the diagram is usually ignored, and the crack may fill with water, which then pushes on the wall over the crack depth. A clayey backfill also swells and creeps, so free-draining granular backfill is preferred wherever it can be had.
Why it matters. Trench collapses are among the most common causes of death on construction sites. A clay trench that stands well in the morning can fail after a few hours as cracks open and fill with water, which is why trenches deeper than about 1.5 m are shored or sloped regardless of how firm they look.
Coulomb's wedge theory
Rankine's theory is neat but assumes a smooth vertical wall. Real walls are rough, and their backs may lean. In 1776, nearly a century before Rankine, Coulomb took a more direct route: he treated the soil behind the wall as a rigid wedge sliding on a plane, and balanced the forces on it.
The forces on the wedge are its weight W, the soil reaction R on the slip plane at an angle φ to its normal, and the wall thrust P at an angle δ, the angle of wall friction, to the normal on the wall. Trying different slip planes gives different values of P; the largest is the active thrust, and for the passive case the smallest is the passive resistance.
Coulomb's theory can handle an inclined wall back, a sloping backfill and wall friction together. Wall friction reduces the active thrust a little and increases the passive resistance a great deal, but for large δ the plane-wedge assumption makes passive values unsafe, so curved slip surfaces are used. For irregular backfills or line loads, Culmann's graphical method repeats the wedge analysis on a drawing.
When δ = 0, the wall is vertical and the backfill level, Coulomb's result equals Rankine's.
Why it matters. For tall walls with rough concrete backs, using Coulomb with a realistic δ, often about two-thirds of φ, gives a lighter and still safe design.
Types of retaining walls and their stability
Retaining structures fall into two families:
- Externally stabilised walls hold the soil by their own weight or stiffness. The soil only loads them. Examples are gravity walls of masonry or mass concrete, cantilever walls of reinforced concrete with a stem fixed into a base slab, crib walls of interlocking members filled with granular soil, gabion walls of wire-mesh boxes filled with stones, and sheet-pile walls of interlocking steel sections driven into the ground.
- Internally stabilised walls make the soil part of the structure. In reinforced earth, strips or geogrids laid in the backfill are tied to facing panels, and friction between soil and strip holds the face. Soil nailing drives steel bars into an existing slope, anchored in the stable zone behind the slip surface.
A geotechnical engineer checks a wall for three main ways of failure.
1. Overturning about the toe. The thrust tries to tip the wall forward. The wall's weight and any soil resting on its base resist:
FoS (overturning) = sum of resisting moments about the toe / sum of overturning moments about the toe
A value of about 2 is commonly used.
2. Sliding along the base. The horizontal thrust must be resisted by friction under the base:
FoS (sliding) = μ ΣV / ΣH, usually required to be at least 1.5
Passive resistance in front of the toe adds to the resistance but is often ignored, since the soil there may be dug away.
3. Base pressure and bearing. The resultant of all forces rarely passes through the centre of the base. If it falls at an eccentricity e from the centre of a base of width B, the pressure on the soil varies from toe to heel:
σmax, min = (ΣV / B)(1 ± 6e/B)
To avoid tension under the heel, e must be within B/6, the middle third of the base. σmax must also be below the safe bearing capacity of the soil. A fourth check, deep-seated slip of the wall together with the ground below it, is done like a slope stability check.
A worked case puts numbers on this. A 5 m gravity wall in concrete (24 kN/m³) with a 2.7 m base retains sand with γ = 17.5 kN/m³ and φ = 32°, sloping at 15°, with μ = 0.5 at the base.
Rankine gives Ka ≈ 0.34 and Pa ≈ 74.4 kN/m, parallel to the slope. The sliding factor comes to about 1.51, and overturning to about 3.35. The resultant falls 0.05 m from the centre, well within B/6, and the base pressure ranges from about 152 kPa at the toe to 9 kPa at the heel.
Why it matters. A wall that is strong enough as a structure can still slide or tip if its base is too narrow. Widening the heel, so that more soil weight rests on it, is often the cheapest fix.
Try it yourself. The free retaining wall tool on ujjwalinfra takes a wall's height, base and backfill properties and works out the earth pressure, the three factors of safety and the base pressure, so you can see which check governs as you change the base width.
Descriptive lens: how this topic is asked in written papers
Written papers test this chapter in four main ways:
- Explain at-rest, active and passive pressure with wall movement and Mohr circles.
- Derive Rankine's Ka and Kp, or the depth of tension cracks in clay.
- Compute the pressure diagram and thrust for surcharge, water table and layered backfill.
- Check a gravity or cantilever wall for overturning, sliding and base pressure.
Practice questions (our own, not previous-year questions).
- Using Mohr circles, explain the active and passive states of earth pressure. Show that the slip planes make 45° + φ/2 and 45° − φ/2 with the horizontal. (10 marks)
- Derive the expression for the depth of tension cracks in a c-φ backfill. Hence find the height to which a vertical cut can stand unsupported in a clay with c = 30 kPa, φ = 0 and γ = 19 kN/m³. (10 marks)
- A 6 m high retaining wall with a smooth vertical back retains sand with γ = 18 kN/m³, γsat = 20 kN/m³ and φ = 30°. The water table rises to 2 m below the top after heavy rain. Draw the pressure diagram, find the total thrust and its point of action, and comment on the role of drainage. (15 marks)
Answer plan for question 3.
- State Rankine's assumptions and find Ka = 1/3.
- Above water: pressure rises from 0 to Ka γ × 2 = 12 kPa at 2 m.
- Below water: soil pressure rises from 12 kPa by Ka γ′ z, with γ′ ≈ 10.2 kN/m³, reaching about 25.6 kPa at the base; add water pressure from 0 to 9.81 × 4 ≈ 39.2 kPa.
- Split the diagram into triangles and a rectangle, add their areas for the thrust (about 166 kN/m) and take moments for its height above the base.
- Compare with the dry case (about 108 kN/m) and conclude that a working drain behind the wall removes most of the extra load; specify weep holes and a graded filter.
Quick revision
- Active < at rest < passive; active needs tiny movement, passive about ten times more.
- K0 = 1 − sin φ′ for normally consolidated soil.
- Active slip plane at 45° + φ/2, passive at 45° − φ/2, to the horizontal.
- Rankine: Ka = (1 − sin φ)/(1 + sin φ), Kp = 1/Ka; Pa = ½ Ka γ H² at H/3.
- Surcharge adds Ka q over the full height.
- Below water: γ′ for soil, plus full water pressure γw hw.
- c-φ soil: pa = Ka γ z − 2c √Ka; zc = 2c/(γ √Ka); Hc = 4c/(γ √Ka), or 4c/γ for φ = 0.
- Coulomb adds wall friction δ and handles inclined walls and sloping backfill.
- Wall checks: overturning about the toe, sliding μΣV/ΣH ≥ 1.5, e ≤ B/6, σ = (ΣV/B)(1 ± 6e/B).